MD40-125,SMC真空發(fā)生器樣本
企業(yè)QQ:2880626087
電話;021-69001039
手機(jī);17321017802(微信)
郵箱;17321017802@163.com
聯(lián)系人;周彩云
地址:上海市嘉定區(qū)江橋嘉涌路99弄6號713室
1. Avoid energizing the solenoid valve for long periods
of time.
If a solenoid valve is energized for a long period of time, the
coil will get hot and the performance may be reduced. Additionally,
each day. Periods of energization can be shortened by using a
Continuous energization of the solenoid valve should be less
than 10 minutes in duration and the energization period should
be shorter than the non-energized period. Take measures for
any heat radiation so that the temperature is within the range
of solenoid valve specifications when the solenoid valve is
the peripheral equipment in close proximity may also
be badly affected. Use a low wattage solenoid valve when the
normally opened or latching type solenoid valve. But, do not
energize the coil on both A and B sides simultaneously when
using the latching type.
Never use the vacuum equipment more than the operating
supply pressure range as this may cause damage to the product
resulting in potentially dangerous operation.
mounted on the control panel. Please pay special attention to
any temperature increases when a manifold type with 3 stations
or more is energized continuously or when three individual
units are placed in close proximity.
2. Use the vacuum equipment within the operating
supply pressure range.
When the operating with a lower supply pressure, the vacuum
performance will be reduced and the poppet valve will cause
malfunction.
solenoid valve is energized continuously or when the duration
of the energization is longer than the non-energized period
MD40-125,SMC真空發(fā)生器樣本
021-39526589
網(wǎng)址:oo-css.cn
地 址:上海市嘉定區(qū)嘉涌路99弄
6號樓713室